Skip to product information
Hanna Checker HC HI772 colorimètre alcalinité récifal plage 0,0 à 20,0 dKH

HI772 Hanna Checker HC Alkalinity — Reef Colorimeter 0.0 to 20.0 dKH - Hanna

$69.95

Available

Hanna Checker HC HI772 pocket colorimeter for reef alkalinity

The Hanna Checker HC HI772 is a pocket colorimeter dedicated to measuring alkalinity in marine and reef aquariums. It bridges the gap between colour-comparison test kits (eye-balled readings, prone to error) and expensive lab photometers. A fixed-wavelength LED (610 nm) and a silicon photocell detector deliver lab-grade precision in a housing that fits in one hand.

In practical use, this Checker HC lets you monitor reef KH in dKH — the standard unit in European reef keeping. Matched reagent: HI772-26, 25 tests per bottle.

What this Checker brings to a reef keeper

  • Digital readout down to 0.1 dKH — no more eye-balling colour cards.
  • Method: colorimetric method — the same chemistry used by lab instruments.
  • Accuracy ±0.3 dKH ±5 % of reading — solid enough to base dosing decisions on.
  • Single-button operation (Zero + Read) — identical routine every measurement, fewer operator errors.
  • Pocket-size 81.5 x 61 x 37.5 mm, 64 g — fits in a maintenance kit.
  • Uses the dedicated Hanna reagent HI772-26 — controlled chemistry, repeatable readings.

Technical specifications

  • Model: HI772
  • Measurement range: 0.0 to 20.0 dKH
  • Resolution: 0.1 dKH
  • Accuracy: ±0.3 dKH ±5 % of reading
  • Light source: LED at 610 nm
  • Light detector: silicon photocell
  • Method: colorimetric method
  • Power: 1x AAA 1.5 V battery
  • Auto-off: auto-off after 2 to 10 minutes depending on model
  • Environment: 0 to 50 °C, RH max 95 % non-condensing
  • Dimensions: 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5 in)
  • Weight: 64 g (2.25 oz)
  • Warranty: 2-year Hanna Instruments warranty

Measurement procedure

  • Rinse the cuvette with RO water, then with sample water.
  • Fill to the mark, insert the cuvette and press Zero.
  • Add Hanna reagent HI772-26, agitate as per the datasheet.
  • Reinsert the cuvette and press Read — the reading appears on the digital display.
  • Rinse the cuvette immediately with distilled water to prevent residue.

Matched reagent and calibration set

  • Hanna HI772-26 — alkalinity reagents 25 tests — the reagent dedicated to this Checker HC; always use fresh reagents to preserve accuracy.
  • Hanna HI772-11 calibration set — reference standards to verify instrument accuracy between measurement runs (sold separately).

Why get this Checker from ReefSolution

To build a complete reef testing station we also recommend:

Frequently asked questions

Which reagent works with the Hanna Checker HC HI772?

The matched reagent is Hanna HI772-26, sold in packs of 25 tests. Never use a reagent from another Checker model — the chemistry and the measurement LED are different.

How accurate is the HI772 on a reef aquarium?

Accuracy is ±0.3 dKH ±5 % of reading with a resolution of 0.1 dKH — plenty to drive a Ca/KH/Mg dosing routine or monitor a critical reef parameter. Always rinse the cuvette with distilled water and work at a stable temperature.

How do I calibrate or verify the HI772?

Use the Hanna HI772-11 calibration set (sold separately) — certified reference standards run periodically confirm the instrument is still within Hanna's tolerances.