Skip to product information
Hanna HI702-25 réactifs Checker HC HI702 25 tests aquarium récifal marin

HI702-25 Hanna Copper Reagents — 25 Tests for Checker HC HI702 - Hanna

$15.99

Available

Hanna HI702-25 copper reagents — 25 tests for the Hanna Checker HC HI702

The Hanna HI702-25 reagents are the dedicated reagents for the Checker HC HI702, a Hanna Instruments pocket colorimeter that measures copper in reef marine aquariums. Each box holds 25 individual tests, one per measurement. The formula is calibrated to the LED and the chemistry of the Checker HC HI702 — using a reagent from a different model gives wrong and meaningless readings.

In practical use, this reagent pack lets you monitor Aiptasia treatments (Fluke-Solve, coral dips) or copper dosing in a hospital tank.

What these reagents bring

  • Adaptation of the epa method (bicinchoninate) — the same chemistry used in the lab and calibrated to the Checker HC HI702 LED.
  • 25 tests per box — enough for 2 to 6 months of monitoring depending on frequency.
  • Genuine Hanna formulation, made in the same conditions used at the factory to calibrate the colorimeter.
  • Pre-measured sachets — no scale or pipette needed.
  • Reproducible readings when procedure is followed (rinsing, timing, agitation).

Measurement procedure

  • Rinse the cuvette with RO water, then with sample water.
  • Fill to the mark, insert the cuvette and press Zero.
  • Add the contents of one HI702-25 sachet and agitate for the time specified in the Hanna datasheet.
  • Reinsert the cuvette and press Read — the reading appears on the digital display.
  • Rinse the cuvette immediately with distilled water to prevent residue.

Specifications

  • Hanna reference: HI702-25
  • Number of tests: 25
  • Compatible with: for the Hanna Checker HC HI702
  • Parameter measured: copper
  • Range: 0.00 to 5.00 ppm
  • Method: adaptation of the EPA method (bicinchoninate)
  • Storage: dry, room temperature, out of direct sunlight.

Why get these reagents from ReefSolution

Frequently asked questions

How many tests are in a box of Hanna HI702-25 reagents?

25 individual tests — one reading per Hanna Checker HC HI702 measurement. That typically covers 2 to 6 months of tank monitoring.

Can I use Hanna HI702-25 reagents with a different Checker model?

No. Each reagent reference is calibrated to the LED and chemistry of its matched Checker HC. Using another model's reagent produces wrong readings.

How should Hanna reagents be stored to preserve accuracy?

Store dry, at room temperature, out of direct sunlight. Do not open the sachets in advance — the chemistry degrades on contact with humidity.

You may also like